Acta Marisiensis.
|
|
||||||
Year 2024
Volume 21 (XXXVIII), no 1 Year 2023 Volume 20 (XXXVII), no 1 Volume 20 (XXXVII), no 2 Year 2022 Volume 19 (XXXVI), no 1 Volume 19 (XXXVI), no 2 Year 2021 Volume 18 (XXXV), no 1 Volume 18 (XXXV), no 2 Year 2020 Volume 17 (XXXIV), no 1 Volume 17 (XXXIV), no 2 Year 2019 Volume 16 (XXXIII), no 1 Volume 16 (XXXIII), no 2 Year 2018 Volume 15 (XXXII), no 1 Volume 15 (XXXII), no 2 Year 2017 Volume 14 (XXXI), no 1 Volume 14 (XXXI), no 2 Year 2016 Volume 13 (XXX), no 1 Volume 13 (XXX), no 2 Year 2015 Volume 12 (XXIX), no 1 Volume 12 (XXIX), no 2 Year 2014 Volume 11 (XXVIII), no 1 Volume 11 (XXVIII), no 2 Year 2013 Volume 10 (XXVII), no 1 Volume 10 (XXVII), no 2 Year 2012 Volume 9 (XXVI), no 1 Volume 9 (XXVI), no 2 Year 2011 Volume 8 (XXV), no 1 Volume 8 (XXV), no 2 Year 2010 Volume 7 (XXIV), no 1 Volume 7 (XXIV), no 2 Year 2009 Volume 6 (XXIII) |
2024, Volume 21 (XXXVIII), no 1
Adrian DALALAU-RUS, Mihaela BUCUR, University of Medicine, Pharmacy, Science and Technology ”G.E. Palade” of Târgu Mureș, Romania Abstract: Indoor Air Quality is one of the most essential factors for ensuring a healthy and comfortable environment inside the buildings. In order to obtain precise and reliable measurements for IAQ, it is necessary to implement a pretesting phase and to perform an analyze of the the data resulted before using the measurement device Testo, according to standards: ISO 7730 and ASHRAE 55. Pretesting is important to identify and eliminated possible errors or external factors which can influence in the end the measurement data all of this so the quality of the data can be improved. This paper aims to analyze a data series of IAQ measurements by using a measurement device, special dedicated for monitoring and evaluation of different ventilation systems. Data taken out of the monitoring phase is processed and the results show the issues with the existing air ventilation systems as well as the potential improvement solutions for the identified nonconformities. The usage of the standards ISO 7730, ASHRAE 55 and Testo measuring device has a big potential in assuring good and reliable measurements of the IAQ. It is important to highlight the importance of pretesting phase and the analyze of the measurement data in order to ensure a good evaluation and finally a sum of solutions focused on providing healthy and comfortable environments. DOI: https://doi.org/10.62838/amset-2024-0004 Pages: 19-26 View full article |
||||||
Update: 19-Jun-2024 | © Published by University Press |