Acta Marisiensis.
Seria Technologica



ISSN 2668-4217
ISSN-L 2668-4217
(Online)


Română

HomeEditorial boardSubmit paperPublication ethicsContactIndexing
Year 2023
Volume 20 (XXXVII), no 1
Volume 20 (XXXVII), no 2

Year 2022
Volume 19 (XXXVI), no 1
Volume 19 (XXXVI), no 2

Year 2021
Volume 18 (XXXV), no 1
Volume 18 (XXXV), no 2

Year 2020
Volume 17 (XXXIV), no 1
Volume 17 (XXXIV), no 2

Year 2019
Volume 16 (XXXIII), no 1
Volume 16 (XXXIII), no 2

Year 2018
Volume 15 (XXXII), no 1
Volume 15 (XXXII), no 2

Year 2017
Volume 14 (XXXI), no 1
Volume 14 (XXXI), no 2

Year 2016
Volume 13 (XXX), no 1
Volume 13 (XXX), no 2

Year 2015
Volume 12 (XXIX), no 1
Volume 12 (XXIX), no 2

Year 2014
Volume 11 (XXVIII), no 1
Volume 11 (XXVIII), no 2

Year 2013
Volume 10 (XXVII), no 1
Volume 10 (XXVII), no 2

Year 2012
Volume 9 (XXVI), no 1
Volume 9 (XXVI), no 2

Year 2011
Volume 8 (XXV), no 1
Volume 8 (XXV), no 2

Year 2010
Volume 7 (XXIV), no 1
Volume 7 (XXIV), no 2

Year 2009
Volume 6 (XXIII)

2023, Volume 20 (XXXVII), no 1

Study of the Exoskeletons Lifespan in the Intensive Care Units

Author(s):
Liviu Cristian CHIS, Monica CHIS, Flaviu MOLDOVAN, Liviu MOLDOVAN
“George Emil Palade” University of Medicine, Pharmacy, Science, and Technology of Targu Mures, Romania

Abstract:
The exoskeletons surface as useful devices in alleviating the Intensive Care Units (ICU) medical stuff’s quality of life. A goal of manufacturers and users of exoskeletons is to determine the probability of proper functioning and increase their lifespan. Considering the extremely small number of exoskeletons for which the durations (cycles) of operation are known, in order to be able to make predictions on the characteristics of the average durations of operation, we used the bootstrap method. Through this method, starting from a small number of data collected from the exploitation of exoskeletons, a desired number of data "similar" to real data is obtained. We used the data of 10 exoskeletons of the same type and their operating times with which 2000 replicates were generated. The data were processed using the EasyFit program and the functional probabilities of the exoskeletons were deduced. A pilot study was performed in order to find the usefulness of using a passive or active torso support exoskeleton in the ICU for prone positioning. It demonstrated a lower degree of fatigue in the subjects who used the exoskeletons.

DOI: https://doi.org/10.2478/amset-2023-0002

Pages: 10-16

View full article
Update: 21-Mar-2024 © Published by University Press